About Modbus Monitor Advanced
Android Modbus Master/Client and Slave/Server for phones and tablets. The Modbus Monitor utility is simple but have many advanced features unmatched even by PC based standards. This is the only Modbus App in the Android store with three Apps in one!!! (Modbus Master, Modbus Server, and Sensors Server in Modbus TCP).
> Modbus Channels: Bluetooth, Ethernet, Wi-Fi, RS232/485 USB Serial ports (check compatibility below)
> Protocols: Modbus TCP, Enron/Daniels TCP, Modbus RTU over TCP, Modbus UDP, Modbus RTU over UDP, Modbus TCP Slave/Server, Modbus RTU, Modbus Serial ASCII
> Sensor Server: Read your phone's sensors (Gyro, GPS, *Cell Phone Tower, etc.) remotely with built-in Modbus Sensor Server
> *Log or Export Data: Log Register values to your private Google Spreadsheet!!! Great for Cloud Storage from multiple devices. Also exports register values in CSV file to device's local storage. > Import/Export: CSV format from Internal/External Memory or Email
> Languages: German, Spanish, French, Italian, Japanese, Polish, Russian, and Chinese
> Modbus Functions: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto Pick
> Allows "Simple" (6 digit Input) or "Advanced" (full modbus) input modes
> *Simple push to write feature that allows writing pre-set value at the push
> *Convert Modbus Integer Values to Text (Coded Message or Status Converter)
> Data Conversion: Unsigned, Signed, Hex, Binary, Long, Double, Float, String, BCD formats, Unix Epoch Time, PLC Scaling (Bipolar/Unipolar Analog ADC value conversion)
> Pro Tuning Options: Interval, Inter-Packet Delay, Link-Timeout, Actual RX/TX Counts, Baud Rate, Stop Bits, Data Bits, Handshaking
> Bluetooth Requirement
1. Your device must have Bluetooth Radio that supports SPP profile (RFCOMM Secure or Insecure)
2. See "ModbusMonitor.com" or email help@modbusmonitor.com for help
3.See below for hardware requirements
> USB-to-Serial Port Requirement, USB OTG Serial Ports>> RS232/422/RS485
Your device must meet all of the THREE requirements.
1. Your device must be Android version 3.2 or newer
2. Your device must support USB Host or OTG interface
3. Your USB-to-Serial Port dongle must contain one of following chipsets: >FTDI [FT230X, FT231X, FT234XD, FT232R, or FT232H], Prolific [PL2303HXD, PL2303EA, or PL2303RA], SiLab [CP210x], QinHeng CH34x
4. RS485: Tested with "no echo" setting turned ON.
More: www.modbusmonitor/guide/serialport
> Feedback
www.ModbusMonitor.com contains online form in “Feeback” section for those who are interested providing constructive feedback or feature request.
> Help
- www.modbusmonitor.com/help
- email: help@modbusmonitor.com
by X####:
It is good industrial applications and good technical support