About ALTIVAR Wi-Fi
ENG:
App tester ALTIVAR devices via TCP / IP protocol Modbus.
Connect via Wi-Fi with variable speed drives Altivar 32-61-71-Process.
With an access-point, connecting the Ethernet channel of the drive to the wireless network will be able to control the motor.
Using the ethernet card inserted in the drive (ATV32-61-71) or the integrated Ethernet port (ATV Process)
It is sufficient to perform a factory reset and then connect with the inverter.
Will be sufficient to know the IP address of the device, connect with the app (page LOG) and follow the instructions provided by the INFO page.
The application, identified the type of Altivar that is connected, it will allow you to configure (page SETUP) the drive with IO-Profile and by use of IO-Scanner service, then you will control the motor (page PILOT).
From REQ page you can read / write the values of the variables within the map data of the inverter.
NOTE: if You are in PILOT page and You go in another page You must returned in PILOT page before the time-out elapsed otherwise the ATV falls in communication error with the motor in stop.
In this case You must go in PILOT page and press the RESET FAULT button and then You will re-control the motor.
ITA:
App tester per ALTIVAR devices via TCP/IP protocollo Modbus.
Connettersi via Wi-Fi con variatori di velocità gamma Altivar 32 - 61 - 71 - Process.
Per mezzo di un access-point, collegando il canale Ethernet del variatore alla rete wireless sarà possibile comandare il motore.
Utilizzando la scheda ethernet inserita nel variatore (ATV32-61-71) o la porta ethernet integrata (ATV Process) è sufficiente eseguire un reset di fabbrica e quindi collegarsi con con l'inverter.
Sarà sufficiente conoscere l'indirizzo IP del device, connettersi con l'app (pagina LOG) e seguire le indicazioni fornite dalla pagina INFO.
L'applicazione, identificato il tipo di Altivar a cui è connessa, consentirà di configurare (pagina SETUP) il variatore con il Profilo-IO e utilizzerà il servizio IO-Scanner per comandare il motore (pagina PILOT).
Dalla pagina REQ sarà possibile leggere/scrivere i valori delle variabili presenti all'interno della mappa dati dell'inverter.
NOTA: quando si è nella pagina PILOT e si esegue un cambio pagina è opportuno ritornare prima che il time-out scada e il motore si ferma. Se accade cio' sarà sufficiente ritornare nella pagina PILOT eseguire un RESET FAULT e riprendere il controllo del motore. ENG:
App tester ALTIVAR devices via TCP / IP protocol Modbus.
Connect via Wi-Fi with variable speed drives Altivar 32-61-71-Process.
With an access-point, connecting the Ethernet channel of the drive to the wireless network will be Able to control the motor.
Using the ethernet card inserted in the drive (ATV32-61-71) or the integrated Ethernet port (ATV Process)
It is sufficient to perform a factory reset and then connect with the inverter.
Will be sufficient to know the IP address of the device, connect with the app (page LOG) and follow the instructions provided by the INFO page.
The application, Identified the type of Altivar That is connected, it will allow you to configure (page SETUP) the drive with IO-Profile and by use of IO Scanner service, then you will control the motor (page PILOT).
From REQ page you can read / write the values of the variables Within the map data of the inverter.
NOTE: if You are in PILOT page and You go to another page You must returned in PILOT page before the time-out elapsed otherwise the ATV falls in communication error with the motor stopped.
In this case You must go in PILOT page and press the RESET button and then FAULT You will re-control the motor.
ITA:
App tester ALTIVAR devices via TCP / IP protocol Modbus.
Connect via Wi-Fi with variable speed drives Altivar range from 32 to 61 - 71 - Process.
By means of an access point, connecting the Ethernet channel of the drive to the wireless network will be able to control the motor.
Using the ethernet card inserted in the drive (ATV32-61-71) or the integrated Ethernet port (ATV Process) is sufficient to perform a factory reset and then connect with the inverter.
Will be sufficient to know the IP address of the device, connect to the app (page LOG) and follow the instructions provided on page info.
The application, identified the type of Altivar connected to it, will allow you to configure (page SETUP) the drive with Profile-IO and IO Scanner will use the service to control the motor (page PILOT).
REQ from the page you can read / write variable values inside the map data of the inverter.
NOTE: when you are on the page PILOT and you run a transition is necessary to return before the time-out expires and the engine stops. If they are doing this' will be enough to return the page PILOT RESET the FAULT and regain control of the engine.